Water vapour transmission rate (WVTR)/ Sd- value (water vapour diffusion-equivalent air layer thickness)
Determination of the Sd value according to the gravimetric method on diffusion open and diffusion inhibiting materials with Sd values of approx. 0.03- 10 m ( equivalent to a WVTR of approx. 4- 800 g/(m²xd) depending on the material and test conditions) as a quintuple determination. For diffusion-inhibiting, diffusion-blocking and diffusion-proof materials with Sd values of approx. 10- >1500 m (corresponds to a WVTR of approx. 0.005- 125 g/(m²xd) depending on the material and test conditions), we recommend the more rapid and more cost-effective electrolysis method (then deviating from the standard as a double determination).
In short — AI-generated
This test determines how much water vapor passes through a packaging material under defined temperature and humidity conditions. Depending on the material's barrier properties, we use either the gravimetric cup method, which measures weight change over time, or the electrolytic method, which uses a sensor to detect moisture transmission.
The resulting Sd-value indicates the thickness of a static air layer that would provide the same resistance to water vapor as the tested material. This value allows developers to compare different films and ensure the packaging provides the necessary moisture protection for the specific product inside.
Text is AI-generated; based on test method data curated and verified by Innoform.
Standard Tests
WVTR/ Sd- value breathable materials
Specific Norm: DIN EN ISO 12572
Determination of the Sd- value (water vapor diffusion equivalent air layer thickness) of building materials and products, which used as permeable (breathing) materials, gravimetric measurement according to DIN EN ISO 12572 / DIN EN 12086 (suitable for Sd-values in the range of approx. 1 - 100 m).
WVTR / Sd value water vapour barrier materials
Specific Norm: DIN EN 1931
Determination of the SD value (water vapor diffusion equivalent air layer thickness) of building materials and products that are used as vapor barrier, electrolytic measurement according to ISO 15106-3 (suitable for Sd-values in the range of approx. 50 - >1500 m).