storage test/ accelerated aging in explosion protected heating chamber (controlled temperature)
Storage tests with or without filling good for estimating the long-term stability of materials and packages. The storage tests, depending on the requirements, could be carried out in lab drying oven (convection), refrigerator, explosion-protected heating chamber (e.g. solvent-based media,T1- T3 max 105 °C;T 4 max. 70 °C), climate chamber (humidity and temperature controlled, temperature and humidity cycles possible). Please select the appropriate method to avoid unnecessary costs.
To prepare an offer we need the following information:
What type of packaging should be tested (size, filling volume)?
How many packages should be stored?
Are the packages empty or do they have to be emptied before testing?
Which contents are involved (CAS no./ safety data sheet)?
How long should the packages be stored?
Under what ambient conditions should the packages be stored (temperature, controlled relative humidity)?
In short — AI-generated
In this test, packaging materials or filled packages are stored under defined temperature and humidity conditions over a specific period to simulate aging processes. For volatile or solvent-based contents, we use explosion-protected heating chambers to ensure safety while maintaining precise environmental control.
The results provide data on the long-term stability and shelf life of the packaging system and its interaction with the contents. This information helps developers verify that the packaging maintains its protective function and integrity throughout the intended product lifecycle.