Compliance work

Overall migration Sensory analysis

Material analysis

Mechanical properties

permeation

PPWR/ Recycling

10 ppb screening or NIAS screening (non-target analysis) semiquantitative

Semi-quantitative screening for the presence of NIAS (non-intentionally added substances) or some SML substances by GC-MS/FID after migration with food simulant ethanol 95% or ethanol 50% for foods with hydrophilic or lipophilic properties or simulant E (poly(2,6-diphenyl-p-phenylene oxide or Tenax ®) for dry foods. In principle, substances with molecular weights of approx. 100 - 700 Dalton (or approx. 100 -700 g/mol) can be detected with a limit of detection of 0,01 mg/kg food (simulant) (=10 ppb).

In short — AI-generated

This test checks for the presence of non-intentionally added substances (NIAS) in packaging materials by using gas chromatography-mass spectrometry (GC-MS) after migration with food simulants such as ethanol or Tenax. The test can detect substances with molecular weights between 100 and 700 Dalton. The migration is done with different food simulants depending on the type of food, such as hydrophilic or lipophilic properties.

The resulting value indicates the presence and approximate quantity of NIAS in the packaging material, with a detection limit of 10 parts per billion (ppb). This information is used to assess the safety of packaging materials for food contact. The test results help packaging developers and buyers to ensure compliance with food safety regulations and to identify potential risks associated with packaging materials.

Text is AI-generated; based on test method data curated and verified by Innoform.

Test Method Group: specific migration

Norms:

Required Sample Amount: 5 x DIN A4 per substance and simulant (please label the food-contact side) or 5 articles respectively, packed in aluminium foil

Standard Tests

SML- screening 50% ethanol

Specific Norm: Hausverfahren PV055

For verification of the migration of semi-volatile substances in liquid or pasty fillings (accredited test method)

SML- screening 95% ethanol

Specific Norm: Hausverfahren PV055

For verification of the migration of semi-volatile substances in liquid or pasty fillings (accredited test method)

SML- screening simulant E (Poly(2,6-diphenyl-p-phenylenoxide) (Tenax®))

Specific Norm: Hausverfahren PV055

For verification of the migration of semi-volatile substances in dry fillings (accredited test method).

Headspace-Screening

Specific Norm: Hausverfahren (externer Anbieter)

Testing for volatile compounds (operated by accredited external provider)