Compliance work

Overall migration Sensory analysis

specific migration

Material analysis

Mechanical properties

permeation

PPWR/ Recycling

GC-MS- Screening (non-target analysis) semiquantitative

GC-MS (gas chromatography coupled with mass spectrometry) screening is a method for the comparative, semi-quantitative evaluation of liquid samples with regard to identity, purity and presence of impurities. The substances detectable by this method are, as with any method limited, here by their molar mass and polarity. The method can be used, for example, to analyze solvent samples and solvent-based surface extracts for impurities. A typical field of application is the investigation of adhesion problems from the printing, laminating and labeling sector. Substances with molecular weights of appr. 100- 700 Dalton (resp. app. 100- 700 g/mol) are principally detectable.

Test Method Group: Material analysis

Norms:
  • In-house method PV055 (2024-11) 10 ppb screening of commodities by GC-MS/FID

Required Sample Amount: Depending on the task, e.g. 2 x DIN A4 or 2 articles, 100 g material; 100 mg liquid